Subscriptions

Fujitsu PRIMERGY CX2550 M2 Dual Socket Server Node

Standard server node for PRIMERGY CX400 M1 multi-node server system

[CX2550M2]

More Image(s)

The PRIMERGY CX2550 M2 is a compact server node enabling highest computing density with four independent servers in 2U. It is ideal for high performance computing, hosting, and hyperconverged stacks as well as in dedicated Big Data environments.
Availability: In stock

For details on how to purchase the Fujitsu PRIMERGY CX2550 M2 Dual Socket Server Node, please click the button below to send us your details and brief requirements. We can then quote you accordingly.

Details

PRIMERGY CX scale-out systems are the ideal basis for cloud, hyper-converged and high performance computing solutions.

They provide data centers as well as branch offices with massive computing power for virtualized environments.

Complex calculations as well as consolidation and high-availability scenarios.

Primergy CX2550 M2

The PRIMERGY CX2550 M2 is a compact server node enabling highest computing density with four independent servers in 2U. It is ideal for high performance computing, hosting, and hyperconverged stacks as well as in dedicated Big Data environments.

an aggregated scaleout architecture

Combined in a PRIMERGY CX400 M1 multi-node system the servers provide an aggregated scaleout performance of a total of 8 CPUs of the latest Intel® Xeon® processor E5-2600 v4 product family, 64 DDR4 memory DIMMs and up to 24 storage drives in a condensed 2 U rack enclosure.

With a huge performance potential, high energy efficiency and at the same time attractive investment costs the PRIMERGY CX2550 M2 provides great versatility to match even ambitious workloads.

High end HPC server nodes

  • Four PRIMERGY CX2550 M2 server nodes, each with two processors, 16 DDR4 memory DIMMs, and up to six local storage drives can be smartly packaged into a condensed 2U rack enclosure.
  • 50% less rack space used as compared to equivalent standard rack servers. Higher server density results in more performance per rack unit.

Latest technology

  • Up to two Intel® Xeon® processor E5-2600 v4 product family with up to 22 cores and 55 MB cache, advanced Turbo Boost 2.0 technology, Hyper Threading, two accelerated QPI links and internal Memory Management Unit.
  • 16 DIMMs per server node with up to 1,024 GB DDR4 memory and up to 2,400 MHz DRAM bandwidth.
  • Cool-safe® Advanced Thermal Design enables operation in a higher ambient temperature.

Latest technology

  • Boost your general computing performance by up to 38% compared to the previous generation.
  • The new DDR4 memory technology provides higher performance with lower power requirements.
  • Each additional degree in the data center means approximately 5-6 percent less energy costs for air-conditioning.

Shared infrastructure and easy serviceability

  • Server nodes share central cooling fans and hot-plug power supplies in the 2U PRIMERGY CX400 M1 chassis.
  • Hot-plug for server nodes, power supplies and disk drives enable enhanced availability and easy serviceability.
  • Decreased energy consumption, lower investment, yet still redundant operation. Lower energy budgets for a comparable performance as with standard rack servers.
  • Each single server can be serviced without affecting the other nodes in the chassis. Redundancy for shared components provides uniform higher availability

Optional liquid cooling solutions

  • The optional direct to chip hot water (40 degrees / 105 degrees Fahrenheit) based cool central liquid cooling captures between 60-80% of the servers heat
  • Removes heat directly from CPUs and memory modules within the server, eliminating the need to cool these components
  • Helps to reduce data center cooling costs by over 50% and lead to less power draw of servers
  • Allows for 2.5-5x higher data center density to realise even ambitious projects
Part No. CX2550M2
Manufacturer Fujitsu
End of Life? No
Height 4
Width 17.5
Depth 52
Weight [Kg] 5.00
CPU Socket(s) 2 x Intel® Xeon® E5-2600v4 processors
Compatible CPU(s) E5-2603v4 (6C/6T, 1.70GHz, 15MB, Turbo: No, 6.4GT/s, 1,866MHz, 85W);
E5-2609v4 (8C/8T, 1.70GHz, 20MB, Turbo: No, 6.4GT/s, 1,866MHz, 85W);
E5-2620v4 (8C/16T, 2.10GHz, 20MB, Turbo: 2.30GHz, 8.0GT/s, 2,133MHz, 85W);
E5-2623v4 (4C/8T, 2.60GHz, 10MB, Turbo: 2.90GHz, 8.0GT/s, 2,133MHz, 85W);
E5-2630v4 (10C/20T, 2.20GHz, 25MB, Turbo: 2.40GHz, 8.0GT/s, 2,133MHz, 85W);
E5-2637v4 (4C/8T, 3.50GHz, 15MB, Turbo: 3.60GHz, 9.6GT/s, 2,400MHz, 135W);
E5-2640v4 (10C/20T, 2.40GHz, 25MB, Turbo: 2.60GHz, 8.0GT/s, 2,133MHz, 90W);
E5-2643v4 (6C/12T, 3.40GHz, 20MB, Turbo: 3.60GHz, 9.6GT/s, 2,400MHz, 135W);
E5-2650Lv4 (14C/28T, 1.70GHz, 35MB, Turbo: 2.00GHz, 9.6GT/s, 2,400MHz, 65W);
E5-2650v4 (12C/24T, 2.20GHz, 30MB, Turbo: 2.50GHz, 9.6GT/s, 2,400MHz, 105W);
E5-2660v4 (14C/28T, 2.00GHz, 35MB, Turbo: 2.40GHz, 9.6GT/s, 2,400MHz, 105W);
E5-2667v4 (8C/16T, 3.20GHz, 25MB, Turbo: 3.50GHz, 9.6GT/s, 2,400MHz, 135W);
E5-2680v4 (14C/28T, 2.40GHz, 35MB, Turbo: 2.90GHz, 9.6GT/s, 2,400MHz, 120W);
E5-2683v4 (16C/32T, 2.10GHz, 40MB, Turbo: 2.60GHz, 9.6GT/s, 2,400MHz, 120W);
E5-2690v4 (14C/28T, 2.60GHz, 35MB, Turbo: 3.20GHz, 9.6GT/s, 2,400MHz, 135W);
E5-2695v4 (18C/36T, 2.10GHz, 45MB, Turbo: 2.60GHz, 9.6GT/s, 2,400MHz, 120W);
E5-2697v4 (18C/36T, 2.30GHz, 45MB, Turbo: 2.80GHz, 9.6GT/s, 2,400MHz, 145W);
E5-2698v4 (20C/40T, 2.20GHz, 50MB, Turbo: 2.70GHz, 9.6GT/s, 2,400MHz, 135W);
E5-2699v4 (22C/44T, 2.20GHz, 55MB, Turbo: 2.80GHz, 9.6GT/s, 2,400MHz, 145W)
Memory Slot(s) 16 / 4 channels per CPU with 8 DIMMs per CPU = 16 DIMMs in total
Memory Capacity 1024 GB
Drive Bays up to 6x 2.5-inch (in the PRIMERGY CX400 M1 chassis
HDD Suitability Hard disk drives
HDD SATA, 6 Gb/s, 500 GB, 7,200 rpm, hot-plug, 2.5-inch, business critical HDD SATA, 6 Gb/s, 250 GB, 7,200 rpm, hot-plug, 2.5-inch, business critical HDD SATA, 6 Gb/s, 2 TB, 7,200 rpm, 512e, hot-plug, 2.5-inch, business critical HDD SATA, 6 Gb/s, 1 TB, 7,200 rpm, hot-plug, 2.5-inch, business critical HDD SATA, 6 Gb/s, 1 TB, 7,200 rpm, 512e, hot-plug, 2.5-inch, business critical HDD SAS, 12 Gb/s, 900 GB, 10,000 rpm, 512n, hot-plug, 2.5-inch, enterprise HDD SAS, 12 Gb/s, 900 GB, 10,000 rpm, 512e, hot-plug, 2.5-inch, enterprise HDD SAS, 12 Gb/s, 600 GB, 15,000 rpm, 512n, hot-plug, 2.5-inch, enterprise HDD SAS, 12 Gb/s, 600 GB, 10,000 rpm, 512n, hot-plug, 2.5-inch, enterprise HDD SAS, 12 Gb/s, 600 GB, 10,000 rpm, 512e, hot-plug, 2.5-inch, enterprise HDD SAS, 12 Gb/s, 450 GB, 15,000 rpm, 512n, hot-plug, 2.5-inch, enterprise HDD SAS, 12 Gb/s, 300 GB, 15,000 rpm, 512n, hot-plug, 2.5-inch, enterprise HDD SAS, 12 Gb/s, 300 GB, 10,000 rpm, 512n, hot-plug, 2.5-inch, enterprise HDD SAS, 12 Gb/s, 1.8 TB, 10,000 rpm, 512e, hot-plug, 2.5-inch, enterprise HDD SAS, 12 Gb/s, 1.2 TB, 10,000 rpm, hot-plug, 2.5-inch, enterprise HDD SAS, 12 Gb/s, 1.2 TB, 10,000 rpm, 512e, hot-plug, 2.5-inch, enterprise

Solid state drive
HDD SATA, 6 Gb/s, 500 GB, 7,200 rpm, hot-plug, 2.5-inch, business critical HDD SATA, 6 Gb/s, 250 GB, 7,200 rpm, hot-plug, 2.5-inch, business critical HDD SATA, 6 Gb/s, 2 TB, 7,200 rpm, 512e, hot-plug, 2.5-inch, business critical HDD SATA, 6 Gb/s, 1 TB, 7,200 rpm, hot-plug, 2.5-inch, business critical HDD SATA, 6 Gb/s, 1 TB, 7,200 rpm, 512e, hot-plug, 2.5-inch, business critical HDD SAS, 12 Gb/s, 900 GB, 10,000 rpm, 512n, hot-plug, 2.5-inch, enterprise HDD SAS, 12 Gb/s, 900 GB, 10,000 rpm, 512e, hot-plug, 2.5-inch, enterprise HDD SAS, 12 Gb/s, 600 GB, 15,000 rpm, 512n, hot-plug, 2.5-inch, enterprise HDD SAS, 12 Gb/s, 600 GB, 10,000 rpm, 512n, hot-plug, 2.5-inch, enterprise HDD SAS, 12 Gb/s, 600 GB, 10,000 rpm, 512e, hot-plug, 2.5-inch, enterprise HDD SAS, 12 Gb/s, 450 GB, 15,000 rpm, 512n, hot-plug, 2.5-inch, enterprise HDD SAS, 12 Gb/s, 300 GB, 15,000 rpm, 512n, hot-plug, 2.5-inch, enterprise HDD SAS, 12 Gb/s, 300 GB, 10,000 rpm, 512n, hot-plug, 2.5-inch, enterprise HDD SAS, 12 Gb/s, 1.8 TB, 10,000 rpm, 512e, hot-plug, 2.5-inch, enterprise HDD SAS, 12 Gb/s, 1.2 TB, 10,000 rpm, hot-plug, 2.5-inch, enterprise HDD SAS, 12 Gb/s, 1.2 TB, 10,000 rpm, 512e, hot-plug, 2.5-inch, enterprise
SATA Controller Intel® C610, for up to 6 x 2.5 inch SATA or SSD SW Raid 0/1
RAID Controller RAID 0/1 for internal drives
RAID Options Fujitsu PRAID EP420i RAID 5/6 Ctrl., SAS/SATA 12 Gbit/s, 8 ports int.
RAID level: 0, 1, 10, 5, 50, 6, 60, 2 GB, Optional FBU based on LSI SAS3108
Fujitsu PRAID EP420i, RAID 5/6 Ctrl., SAS/SATA 12 Gbit/s, 8 ports int.
RAID level: 0, 1, 10, 5, 50, 6, 60, 2 GB, Optional FBU based on LSI SAS3108
Fujitsu PRAID EP400i, RAID 5/6 Ctrl., SAS/SATA 12 Gbit/s, 8 ports int.
RAID level: 0, 1, 10, 5, 50, 6, 60, 1 GB, Optional FBU based on LSI SAS3108
USB Port(s) 2 x USB 3.0 (rear)
PCI Slot(s) PCI-Express 3.0 x16 // 2 x (for low profile)
LAN Socket(s) Converged Network Adapter 1 x 40 Gbit/s PCIe 3.0 x8 QSFP+ ( Emulex ) Converged Network Adapter 2 x 10 Gbit/s PCIe 3.0 x8 SFP+ ( Emulex ) Ethernet Ctrl. 2 x 10 Gbit/s PCIe 2.0 x8 SFP+ ( Fujitsu ) Ethernet Ctrl. 2 x 10 Gbit/s PCIe 2.1 x8 RJ45 ( Intel® ) Ethernet Ctrl. 2 x 10 Gbit/s PCIe 3.0 x8 10Gbit/s Eth (RJ45) ( Emulex ) Ethernet Ctrl. 2 x 10 Gbit/s PCIe 3.0 x8 SFP+ ( Emulex ) Ethernet Ctrl. 2 x 1 Gbit/s PCIe 2.1 x4 RJ45 ( Intel® ) Ethernet Ctrl. 4 x 1 Gbit/s PCIe 2.1 x4 RJ45 ( Intel® ) InfiniBand HCA 1 x 56 Gbit/s PCIe 3.0 x8 QSFP for the US market max. one IB HCA 56Gb controller can be installed ( Mellanox ) InfiniBand HCA 1 x PCIe 3.0 x16 QSFP for the US market max. one IB HCA 100Gb controller can be installed ( Mellanox ) InfiniBand HCA 2 x 56 Gbit/s PCIe 3.0 x8 QSFP for the US market max. one IB HCA 56Gb controller can be installed ( Mellanox ) InfiniBand HCA 2 x PCIe 3.0 x16 QSFP for the US market max. one IB HCA 100Gb controller can be installed ( Mellanox )
LAN Controller(s) 2 x 10/100/1000 Mbit/s Ethernet (TCP/IP acceleration)
Standard 3 years Onsite warranty

    Please login to x.com to view...